Skip to content
logo
Commercial & Public Spaces Data Centers Food & Beverage Government & Emergency Response Manufacturing Power, Oil, & Gas Sports & Leisure Transportation & Infrastructure Water & Wastewater Management
feature image

Commercial Roofing

logo-fibertite
Geomembranes

Geomembranes

logo-xr
Architectural Fabrics

Architectural Fabrics

logo-architectural
Keder samples fabricated by Lightweight Structures

Tensioned Fabric Solutions

Lightweight Structures
Innovative Fabric Solutions

Industrial Fabrics

logo

About Seaman Corporation

Seaman Corporation is a privately held, multi-generational family-owned U.S. manufacturer and trusted provider of protective solutions, delivering high-performance industrial coated fabrics since 1949.

Read More
Corporate Responsibility Our Impact Our History Leadership and Governance Careers

Our Insights

Explore Our Insights
Case Studies Competitive Comparisons Blogs Press Room Webinars

Contact Seaman
Corporation

800-927-8578 Send A Message Now

Locations

World Headquarters

Seaman Corporation
1000 Venture Boulevard
Wooster, Ohio 44691

330-262-1111 330-263-6950

Bristol, Tennessee

Seaman Corporation
PO Box 3946
225 N. Industrial Drive
Bristol, TN 37620

423-989-5200 423-989-5215

Whitehall, Pennsylvania

Lightweight Structures
1139 Sumner Avenue, STE 1
Whitehall, PA 18052

610-435-4720 610-465-8866

More ways to Connect

Careers
Credit Application
Lightweight Structures™
Applications Services Products Documents Contact Online Store
Fabric structure part way through a reskin, lift positioned at the wall
Lightweight Structures

Structure Reskins and Fabric Replacement

Extend the life of your existing fabric structure with a replacement cover instead of a full reconstruction. Lightweight Structures engineers and fabricates replacement fabric panels for existing structures, helping you find the right solution for your building while minimizing disruption and keeping your project moving.

Reskin and Repair for Fabric Structures

When a fabric building needs a replacement cover, Lightweight Structures provides:

  • Assistance in fabric selection specifically for reskinning and repairing fabric structures.
  • Engineering support based on knowledge of the most common systems in the industry.
  • Creative dismantle and reskin options that minimize downtime. See our 5-step overview of a turnkey reskin.
  • Connections with specialized turnkey contractors who coordinate installation directly with you.

For many existing fabric structures, the original installation method is not the most efficient way to reskin the building. When a project requires the frame to be detensioned, removing interior liners, electrical systems, and other suspended equipment can add significant cost and disruption. Alternative reskinning methods may allow the replacement fabric to be installed without removing these interior systems—and, in some cases, without disrupting interior operations.

We engineer and fabricate the replacement fabric system and work with our network of certified installation partners to complete the project. For reskins, we coordinate with specialized turnkey contractors responsible for installation. Foundations are specified in our engineering documents and performed by others.

We engineer and fabricate with coated fabrics and films, including those made by our parent company, Seaman Corporation. Since 1949, Seaman has manufactured high-performance coated fabrics in the United States, managing the process from yarn and weaving or knitting through coating and finished membrane.

Crews on aerial lifts and scaffolding at the end wall of a large fabric-covered frame building

Frame-Supported Reskins

The original installation method is not always the right way to put fabric back on. Our engineers evaluate alternative attachment methods, tensioning approaches, and fabric options that may eliminate the need to detension the frame. Depending on the structure, this can help keep interior liners, electrical systems, and finishes in place while reducing disruption to building operations.

Where appropriate, we can also recommend design improvements to help the replacement system perform better than the original. We support both building owners and turnkey contractors throughout fabric replacement projects.

interior of a tensioned fabric structure at the mast

Tensile Reskins

Fabric replacement on a tensile structure requires extensive engineering effort to ensure a successful reskin project. Our process relies on solid engineering data to carefully account for variables like prestress that heavily influence the integrity of the structure. If the design information is missing or unavailable, Lightweight has the capability to reverse-engineer this information to ensure that the replacement fabric, existing frame and foundations can all be safely reused.

From there, we provide comprehensive engineering and design support, fabricating the new tensile cover along with any necessary replacement components to ensure the existing frame and foundations can be safely reused.**

Products for Structure Reskins & Repair

Three white keder strips, cord cores showing at the cut ends, on a black background
Product

Keder

Keder is the rope edge that connects a fabric panel to its frame. It slides into a channel in an aluminum rail, and the rails fit almost any existing frame.

Tensile fabric shade canopy tensioned on a steel frame, backlit by blue sky
Product

Fabrics

Compare PVC-coated polyester, PTFE-glass, ePTFE, fluoropolymer film, polyethylene, solution-dyed woven, and PVC mesh. Selection guidance and free samples.

Ready to Get Started?

Tell us about the structure you need to reskin, including its age, frame type, current fabric, and any available engineering drawings or documentation. We’ll help you evaluate the replacement options for your building.

Schedule a Consultation

Our Industry Insights

Keder panels on the reskinned roof of a frame-supported practice facility
Blogs

5-Step Turnkey Reskin Overview

A five-step walkthrough of a turnkey reskin: replacing the outer fabric and inner liner of a football practice facility with keder panels.

Tensile fabric canopies beneath the Penn State water tower
Case Studies

Penn State Water Tower Tensile Canopies

How PVC-coated polyester canopies, fabricated by Lightweight with Signature Structures, created a unique shade structure at Penn State University.

Radio-frequency welding machine on a fabrication bench, with work gloves resting in front of it
Blogs

Types of Industrial Fabric Welds

A practical guide to RF, hot air, hot wedge, and hot bar welding for coated industrial fabrics, including when to use each method.

Double Coated Keder – IFAI
Press Room

Double Coated Keder – IFAI

IFAI's Specialty Fabrics Review on double coated keder: coated fabric wrapped around an extruded core for wear resistance and longer-lasting panels.

Explore Insights

Start Your Project with Lightweight Structures

Ask a question, request a quote, or request free fabric and keder samples. Expect prompt initial feedback from our team.

Request(Required)
Region(Required)

Frequently Asked Questions

Can you replace the fabric on an existing fabric building?

Yes. Lightweight Structures engineers and fabricates replacement fabric panels for existing frame-supported and tensile structures. The appropriate replacement approach depends on the existing structure, attachment system, fabric requirements, and available engineering documentation.

Can a fabric structure be reskinned without removing interior liners or electrical systems?

In some cases, yes. Alternative attachment and tensioning methods may allow a structure to be reskinned without removing interior liners, electrical systems, or other suspended equipment. Feasibility depends on the structure’s design and existing installation method.

Do I need the original engineering drawings for a tensile reskin?

Original engineering drawings are helpful, but their absence doesn’t automatically rule out a tensile reskin. Because the membrane contributes to the structure’s performance, engineering is needed to establish appropriate design assumptions and assess whether existing structural components can be reused safely.

Can the existing frame and foundations be reused during a reskin?

Potentially. Reuse depends on the existing structure, its condition, available engineering information, and the requirements of the replacement design. Appropriate engineering assessments are needed to determine whether the frame and foundations can safely support the replacement fabric system.

Partners & Memberships